Yk 022-10022-000 Liquid Line Right-Angle Shut-off Valve (Chiller Valve Accessory for Central Air Conditioning)

Yk 022-10022-000 Liquid Line Right-Angle Shut-off Valve (Chiller Valve Accessory for Central Air Conditioning)

Part number 022-10022-000 is a genuine York right-angle manual shut-off valve for the liquid refrigerant line of water-cooled centrifugal chillers. Designed as an isolation valve for high-pressure refrigeration piping, it is installed on the high-pressure liquid line between the condenser, the filter-drier, and the electronic expansion valve.
The valve features a one-piece, forged brass, 90-degree right-angle body with an integrated self-sealing conical valve core, operated via a manual knob. It allows for the isolation of the refrigerant line during maintenance—such as replacing the filter-drier or electronic expansion valve—without requiring a full system refrigerant recovery, thereby significantly reducing maintenance effort. Issues such as valve core seal wear, stem leakage, or internal leakage can lead to slow refrigerant loss, a drop in system pressure, and accelerated saturation of the filter-drier; this is a standard, commonly used spare part for centrifugal chillers.

Send Inquiry
Description
Argument
Products Description

 

Product Name York 022-10022-000 Angle Valve
Model 022-10022-000
Applicable Industries Construction and Commercial
Application Refrigeration compressor
Packaging Cardboard Box
MOQ 1 Piece

Key Product Advantages:
Brass valve body combined with a dual-layer FKM seal; resistant to high-temperature POE refrigeration oil and refrigerant corrosion, ensuring leak-free performance even in environments with persistent oil mist;

90° right-angle outlet design facilitates piping layout in cramped compressor compartments and minimizes fatigue damage caused by line bending;

Simple manual knob operation allows for opening and closing without specialized tools, streamlining maintenance and installation;

Zero-internal-leakage tapered valve core completely shuts off flow when closed, preventing the continued migration of moisture and impurities within the system;



Tags:

Technical parameter
Q1:For refrigeration industry, which brands are your products covering? A1:We produce filter element replacements for brands like,Bitzer, Carrier, Yk, McQuay, Trane, etc…
Q2:Does the price include freight? A2:The quotation is usually the factory price. We can recommend the most economical logistics plan and calculate the freight according to your destination and quantity.
Q3:How to ensure product quality? A3:We have a strict quality control process, and we will carry out multiple inspections before the products leave the factory to
ensure that they meet the standards.
Q4:Why choose us? A4:Product reliability: We are a professional manufacturer . can offer high-quality products at the most competitive prices.
Technical support: We provide technical assistance.
Industry experience: We have over 10 years of experience in the refrigeration equipment service field.
After-sales service: We offer professional after-sales service.
Team collaboration: We have a professional team that can provide you with prompt services and delivery schedules.

Typical product failure symptoms:
1. Internal leakage due to aging of the valve core seal: The pipeline cannot be fully isolated after the valve is closed; continuous refrigerant leakage occurs during maintenance, causing system pressure to drop steadily.
2. Damage to the valve stem sealing gasket: Refrigeration oil and refrigerant slowly seep from the top knob area, leading to a gradual drop in the oil reservoir level.
3. Valve stem corrosion or seizure: The knob cannot be fully opened or closed, resulting in a failure to isolate specific pipeline sections and an inability to replace the filter-drier.
4. Missing or damaged threaded connection gaskets: High-pressure refrigerant leaks from the threaded interface, causing continuous refrigerant loss in the unit.
5. Valve core wear or material loss: Trace amounts of refrigerant continue to flow even when the valve is closed; the filter-drier continuously adsorbs moisture and impurities, leading to premature clogging and an increase in differential pressure.