| Product Name | Trane SEN02133 Immersion Temperature Sensor |
| Model | SEN02133 |
| Applicable Industries | Construction and Commercial |
| Application | Refrigeration compressor |
| Packaging | Cardboard Box |
| MOQ | 1 Piece |
Core Product Functions:
1. Precision Temperature Sensing for Chilled/Cooling Water (Core Function)
Real-time monitoring of inlet and outlet water temperatures provides the fundamental data needed for the main controller to calculate temperature differentials and adjust compressor capacity; these sensors are critical components for energy efficiency control and freeze protection.
2. Interlocked Freeze Protection for Water Circuits
If water temperatures drop below the freeze-protection threshold, the unit automatically activates the water pump and performs a load-reduction shutdown, preventing freeze-induced rupture of heat exchanger tube bundles in the evaporator and condenser during cold weather.
3. Intelligent Load Regulation for Enhanced Energy Efficiency
Compressor loading and unloading are dynamically adjusted based on the chilled water supply/return temperature differential, balancing cooling output with actual load demand to minimize energy consumption.
4. Early Warning for Water Flow Faults and Heat Exchanger Fouling
If the inlet/outlet temperature differential deviates significantly (becoming abnormally high or low), the unit triggers an alert indicating potential heat exchanger scaling or insufficient pump flow, allowing for proactive cleaning and maintenance.
5. Long-term Stability with Linear Platinum Resistance Sensors
Compared to NTC thermistors, platinum resistance sensors exhibit minimal temperature drift, ensuring consistent measurement accuracy over years of operation and eliminating the need for annual calibration.
Tags: Chiller pressure transducer commercial air conditioning pressure detector compressor control spare part cooling system monitoring component HVAC maintenance accessory HVAC pressure probe industrial chiller replacement sensor refrigerant pipeline sensor refrigeration pressure sensor SEN02133 Trane sensor Trane Spare Parts
Technical parameter

Company Profile

Factory Profile
| Q1:For refrigeration industry, which brands are your products covering? | A1:We produce filter element replacements for brands like,Bitzer, Carrier, Yk, McQuay, Trane, etc… |
| Q2:Does the price include freight? | A2:The quotation is usually the factory price. We can recommend the most economical logistics plan and calculate the freight according to your destination and quantity. |
| Q3:How to ensure product quality? | A3:We have a strict quality control process, and we will carry out multiple inspections before the products leave the factory to ensure that they meet the standards. |
| Q4:Why choose us? | A4:Product reliability: We are a professional manufacturer . can offer high-quality products at the most competitive prices. Technical support: We provide technical assistance. Industry experience: We have over 10 years of experience in the refrigeration equipment service field. After-sales service: We offer professional after-sales service. Team collaboration: We have a professional team that can provide you with prompt services and delivery schedules. |
Common product malfunctions:
1. Water circuit temperature fault reported; compressor fails to load/operate
Platinum resistance element open-circuit or connector wiring oxidized; no resistance signal transmitted to the main controller; compressor interlock restricts output.
2. Water temperature readings fluctuate erratically; frequent false shutdowns due to anti-freeze protection
Connector seal failure or damaged shielding layer; electromagnetic interference causes signal instability; main controller misinterprets readings as low temperature and triggers anti-freeze protection.
3. Erratic unit load regulation; cooling capacity fluctuates
Temperature measurement drift; significant discrepancy in water temperature readings by the main controller; frequent compressor loading/unloading cycles; increased energy consumption.
4. Heat exchanger blockage goes undetected; heat exchange efficiency drops sharply
Temperature measurement failure; no feedback on abnormal inlet/outlet temperature difference; long-term scaling on tube bundles; high discharge pressure and increased power consumption.
5. Water ingress causes connector short-circuit; mainboard Pt1000 temperature sensing channel burned out
Condensation/moisture from the mechanical room enters the connector; signal line short-circuit; damage to the main controller’s I/O temperature sensing port.