Products Description

oplus_262176


oplus_262176
| Product Name | Yk 022-10047-000 Manual Refrigerant Isolation Ball Valve |
| Model | 022-10047-000 |
| Applicable Industries | Construction and Commercial |
| Application | Refrigeration compressor |
| Packaging | Cardboard Box |
| MOQ | 1 Piece |
Key Fluid Performance Characteristics of the Ball Valve:
1. Long-lasting, wear-resistant PTFE seal; suitable for continuous, full-load, high-temperature operation.
Compared to NBR rubber seals, PTFE offers superior high-temperature resistance, resistance to refrigerant swelling, and wear resistance. It resists aging and leakage in the continuous high-temperature oil environments typical of data centers, resulting in longer intervals between major overhauls.
2. Rapid 90° on/off operation; safe and efficient sectional isolation.
A 90° turn of the handle completely shuts off the pipeline. This allows for the isolation of specific sections during maintenance and the recovery of refrigerant from those sections alone—eliminating the need to evacuate the entire unit’s refrigerant charge—thereby significantly reducing refrigerant loss and maintenance labor costs.
3. Full-bore, low-flow-resistance design; preserves the unit’s cooling efficiency.
The bore of the spherical valve core matches the pipeline’s internal diameter, ensuring no additional pressure loss during full-load refrigerant circulation. This prevents elevated condensing pressure, frequent high-pressure unloading, and cooling capacity degradation.
4. Bidirectional flow capability; no installation orientation limits; high installation flexibility.
The valve body has no designated inlet or outlet, allowing for installation at any angle—horizontal or vertical. Pipeline prefabrication and on-site welding do not require attention to flow direction, simplifying the installation process.
Tags: 022-10047-000 chiller cut-off valve chiller maintenance fittings commercial air conditioning valve cooling system flow control component HVAC refrigerant valve industrial chiller replacement valve refrigerant pipeline valve refrigeration shut-off valve refrigeration system shutoff valve York spare parts York stop valve
Technical parameter

oplus_262176


oplus_262176
| Q1:For refrigeration industry, which brands are your products covering? | A1:We produce filter element replacements for brands like,Bitzer, Carrier, Yk, McQuay, Trane, etc… |
| Q2:Does the price include freight? | A2:The quotation is usually the factory price. We can recommend the most economical logistics plan and calculate the freight according to your destination and quantity. |
| Q3:How to ensure product quality? | A3:We have a strict quality control process, and we will carry out multiple inspections before the products leave the factory to ensure that they meet the standards. |
| Q4:Why choose us? | A4:Product reliability: We are a professional manufacturer . can offer high-quality products at the most competitive prices. Technical support: We provide technical assistance. Industry experience: We have over 10 years of experience in the refrigeration equipment service field. After-sales service: We offer professional after-sales service. Team collaboration: We have a professional team that can provide you with prompt services and delivery schedules. |
Core Product Features:
1. Sectional isolation for maintenance (Core Feature)
When replacing components such as filter driers, expansion valves, or compressors, valves can be closed to isolate specific piping sections. This allows for the recovery of refrigerant from that section alone—eliminating the need to evacuate the entire system—thereby saving refrigerant and reducing maintenance downtime.
2. Long-term sealing during shutdowns to prevent slow refrigerant leakage
Valves can be closed during extended shutdowns or unit relocation to isolate high- and low-pressure lines, preventing the gradual loss of refrigerant caused by the natural aging of seals over time.
3. Reinforced PTFE sealing, suitable for 24/7 industrial full-load, high-temperature operation
Optimized for chillers in data centers and chemical processing applications, the seal remains stable in high-temperature refrigerant environments, minimizing leakage failures at the valve stem and body.
4. High-flow, non-throttling design; no impact on operational energy efficiency
The straight-through spherical flow path features no flow restrictions or narrowed cross-sections; refrigerant circulates at full load without additional pressure drop, ensuring the unit’s year-round energy efficiency remains unaffected by the valve.
5. Purely mechanical design; no risk of electrical failure
Requires no power supply, coils, or circuit boards, eliminating issues such as solenoid coil burnout or electronic valve-core jamming, making it ideal for continuous, long-term industrial operation.