Welcome to Xinxiang Linghan Refrigeration Equipment Co., Ltd.!

Email

linghan.hvac@foxmail.com

WhatsApp

+86 17275390336

Compatible with 30RB/RQ Industrial Compressors: Brand New Carrier Compressor Electric Oil Heater (Part No. 00PPG000010300)

Compatible with 30RB/RQ Industrial Compressors: Brand New Carrier Compressor Electric Oil Heater (Part No. 00PPG000010300)

The 00PPG000010300 is a crankcase heater specifically designed for Carrier 30RB/RQ series screw compressors. Its primary function is to preheat and maintain the temperature of the compressor's crankcase oil while the unit is shut down. This prevents the excessive dissolution of refrigerant into the oil—a common occurrence in low-temperature environments—which would otherwise lead to oil dilution and lubrication failure. Furthermore, it safeguards against severe malfunctions during unit startup—such as liquid slugging, bearing wear, and oil pump damage—making it a critical component for ensuring both low-temperature protection and stable startup for screw chiller units.

Send Inquiry
Description
Argument
Products Description

Product Name Carrier Electric Oil Heater 00PPG000010300
Model 00PPG000010300
Applicable Industries Construction and Commercial
Application Refrigeration compressor
Packaging Cardboard Box
MOQ 1 Piece

Core Product Advantages
1.Industrial-Grade Durability: Long-Term Stability and Reliability
Constructed from high-temperature-resistant insulating materials, high-purity heating wires, and a thickened aluminum foil thermal conduction layer, this unit offers exceptional resistance to oil, moisture, and corrosion. It is specifically designed to withstand the high-humidity and oil-mist-laden environments typical of equipment rooms, boasting a continuous, trouble-free operating lifespan of ≥50,000 hours—thereby significantly reducing the costs associated with frequent replacements.
2.High Efficiency and Energy Savings: Lossless Preheating
Featuring a standard power output of 150W, the unit combines low power consumption with high preheating efficiency. It operates exclusively when the equipment is shut down, automatically powering off during active operation; this ensures that it adds no extra energy load to the unit’s overall consumption, effectively balancing robust protective performance with energy-saving requirements.
3.Multiple Safety Safeguards: Zero Operational Risk
Incorporating a triple-layer protection system—comprising insulation shielding, thermal fuse protection, and equipment interlocking control—the unit completely eliminates risks associated with short circuits, dry burning, overheating, and electrical leakage. Compliant with UL and CE industrial safety standards, it offers users and maintenance personnel complete peace of mind.
4.Broad Compatibility: Covers the Entire Unit Series
Perfectly compatible with all models in the Carrier 30RB and 30RQ series of water-cooled screw chillers, this product serves as the *only* designated OEM oil heater for this compressor series. It provides a comprehensive, one-stop solution for critical operational challenges, including low-temperature startup, refrigerant dilution, and protection against liquid slugging.



Tags:

Technical parameter
Company Profile

Company Profile

Other Product Images

Other Product Images

Factory Photos

Factory Photos

Q1:For refrigeration industry, which brands are your products covering? A1:We produce filter element replacements for brands like,Bitzer, Carrier, York, McQuay, Trane, etc…
Q2:Does the price include freight? A2:The quotation is usually the factory price. We can recommend the most economical logistics plan and calculate the freight according to your destination and quantity.
Q3:How to ensure product quality? A3:We have a strict quality control process, and we will carry out multiple inspections before the products leave the factory to
ensure that they meet the standards.
Q4:Why choose us? A4:Product reliability: We are a professional manufacturer . can offer high-quality products at the most competitive prices.
Technical support: We provide technical assistance.
Industry experience: We have over 10 years of experience in the refrigeration equipment service field.
After-sales service: We offer professional after-sales service.
Team collaboration: We have a professional team that can provide you with prompt services and delivery schedules.

Product Functions and Benefits
1.Refrigerant Oil Preheating and Thermal Retention: Preventing Refrigerant Dilution
When the unit is shut down and ambient temperatures are low, the heater automatically activates to maintain the oil temperature within a safe range of 25°C to 40°C. This prevents large quantities of liquid refrigerant from dissolving into the refrigerant oil, thereby avoiding a sudden drop in oil viscosity and the subsequent loss of lubrication effectiveness. Consequently, the risk of liquid slugging during startup is completely eliminated at the source.
2.Ensuring Low-Temperature Startup: Reducing Mechanical Wear
In low-temperature environments (such as unheated equipment rooms in winter or during overnight shutdowns), refrigerant oil tends to thicken and lose fluidity. Preheating via the heater maintains the oil at its optimal viscosity, ensuring that the bearings, rotors, and oil pump receive adequate lubrication the moment the compressor starts. This significantly reduces wear during startup and extends the service life of the compressor’s core components by over 30%.
3.Built-in Overheat Protection: Eliminating Safety Hazards
Integrated with a thermal fuse safety mechanism, the unit automatically and permanently disconnects the circuit in the event of anomalies—such as dry burning, thermostat failure, or oil temperatures exceeding 80°C. This prevents heater burnout, oil sump overheating, and insulation degradation, thereby averting the risk of fire and secondary damage to the unit, ensuring maximum safety.
4.Plug-and-Play Compatibility: Seamless Integration with OEM Control Logic
Fully compatible with the control programs of Carrier 30RB/RQ units, the heater operates in perfect synchronization with the unit’s temperature control system: it activates during shutdown and deactivates during operation. Requiring no additional wiring or manual intervention, it functions as a fully automatic, collaborative system that is both stable and reliable.
5.Flexible Contouring Design: Efficient, Uniform Heat Transfer
Utilizing a flexible aluminum foil heating strip structure, the unit conforms perfectly to the curved contours of the compressor’s oil sump. This design ensures a large heat transfer area, high thermal efficiency, and uniform temperature rise—eliminating localized overheating and heating “dead zones.” As a result, the preheating speed is 20% faster than that of traditional rigid heaters.