Welcome to Xinxiang Linghan Refrigeration Equipment Co., Ltd.!

Email

linghan.hvac@foxmail.com

WhatsApp

+86 17275390336

Carrier 00PPG000008100 Temperature Sensor / NTC Thermistor-type Water Temperature Probe – Monitors Chiller Inlet and Outlet Water Temperatures

Carrier 00PPG000008100 Temperature Sensor / NTC Thermistor-type Water Temperature Probe – Monitors Chiller Inlet and Outlet Water Temperatures

The 00PPG000008100 is a Carrier NTC thermistor-type water temperature sensor, serving as a standard, core temperature-sensing component for 30RB/30RQ air-cooled scroll heat pumps and 30XA/30XW/30XQ water-cooled screw chillers.
Featuring an integrated stainless steel probe and a durable, weather-resistant shielded cable, it is designed to monitor the inlet and outlet temperatures of chilled or cooling water. It transmits real-time temperature-resistance signals to the main control board, providing critical data for compressor start/stop operations, load regulation, water flow monitoring, freeze protection, and cooling/heating mode switching. This sensor is a frequently replaced consumable in commercial central air conditioning maintenance and is compatible with Carrier screw and scroll chiller systems.

Send Inquiry
Description
Argument
Products Description

Product Name Carrier 00PPG000008100 Temperature Sensor
Model 00PPG000008100
Applicable Industries Construction and Commercial
Application Refrigeration compressor
Packaging Cardboard Box
MOQ 1 Piece

Core Functions and Features:
1. Real-time Chilled/Cooling Water Temperature Monitoring: Measures the temperature difference between supply and return water to calculate cooling capacity and match compressor load, enabling energy-efficient variable-frequency control.
2. Low-Temperature/Anti-Freeze Protection: Triggers continuous water pump operation and activates electric heating when the water temperature drops below the anti-freeze threshold, preventing water pipes from freezing and bursting in winter.
3. High-Temperature Overload Protection: Reduces compressor load or shuts down the unit when the return water temperature becomes excessively high, preventing high-pressure and high-temperature faults.
4. Water Flow Logic Interlock: Works with the water flow switch to assess water circulation based on temperature changes; disables unit operation if no water flow is detected.
5. Automatic Cooling/Heating Mode Switching: Heat pump models determine the operating mode (cooling or heating) based on water temperature and adjust the control logic for fans and expansion valves.
6. Fault Self-Diagnosis and Alarm: Issues a water temperature sensor fault code in the event of probe disconnection, short-circuiting, or resistance drift, facilitating rapid troubleshooting and maintenance.



Tags:

Technical parameter
Company Profile

Company Profile

Factory Profile

Factory Profile

Q1:For refrigeration industry, which brands are your products covering? A1:We produce filter element replacements for brands like,Bitzer, Carrier, Yk, McQuay, Trane, etc…
Q2:Does the price include freight? A2:The quotation is usually the factory price. We can recommend the most economical logistics plan and calculate the freight according to your destination and quantity.
Q3:How to ensure product quality? A3:We have a strict quality control process, and we will carry out multiple inspections before the products leave the factory to
ensure that they meet the standards.
Q4:Why choose us? A4:Product reliability: We are a professional manufacturer . can offer high-quality products at the most competitive prices.
Technical support: We provide technical assistance.
Industry experience: We have over 10 years of experience in the refrigeration equipment service field.
After-sales service: We offer professional after-sales service.
Team collaboration: We have a professional team that can provide you with prompt services and delivery schedules.

Product Structural and Material Advantages:
1. Stainless Steel Sealed Probe: Features an integrated, seamless encapsulated thermal sensing core; waterproof and rust-resistant; withstands long-term immersion in antifreeze without corrosion; offers rapid thermal conductivity and quick temperature response.
2. Brass Mounting Base: Threaded design fits standard unit thermowells for easy installation and removal; ensures uniform heat conduction and eliminates temperature measurement lag.
3. Double-Shielded Cable: Built-in shielding layer isolates electromagnetic interference from variable frequency drives (VFDs) and contactors, preventing temperature reading fluctuations and false alarms.
4. High/Low-Temperature Resistant Sheath: Specialized gray refrigeration-grade cable; remains flexible and crack-free at -40°C; resists aging and embrittlement in high-temperature equipment rooms or under direct outdoor sunlight.
5. Fully Sealed Potting Process: High-temperature epoxy seal at the probe tail prevents the ingress of condensation or oil, which could otherwise cause sensor short-circuits or failure, thereby extending service life.

Leave Your Message